Marine, OIL,GAS & Petrochemical Cables |
|
|
European lightweight marine cables to IEC 60092-3
XT-331 fire resistant marine cables manufactured to IEC 60092-353. Are ideal for applications where the risk of mechanical damage is low and circuit integrity is required in the event of a fire. Their lightweight and small outer diameters saves weight and wiring space providing cost savings on tray and containment.
Technical Information
Operating temperature: |
-40ºC to +85ºC
(Some +100ºC versions are also available) |
Smoke emission: |
IEC 61034-1 & 2 |
HCl gas emission: |
IEC 60754-1 & 2 |
Flame retardant: |
IEC 60332-3A ( IEC 60332-3-25 ) |
Fire resistant: |
IEC 60331- 3 hours @750ºC |
Approvals: |
Lloyds, DNV, ABS, or BV and Rina.
Approvals may vary between manufacture brands.
Please tell us at time of enquiry if you have a specific preference. |
Technical Data
No. of Cores
& mm² |
Approx. Weight
Kg/Km |
Nominal
O/D mm |
2x1.5 |
90 |
9.0 |
2x2.5 |
115 |
9.5 |
2x4 |
165 |
11.5 |
2x6 |
220 |
13.5 |
2x10 |
335 |
15.0 |
2x16 |
485 |
17.0 |
3x1.5 |
110 |
10.0 |
3x2.5 |
135 |
10.5 |
3x4 |
200 |
11.0 |
3x6 |
270 |
12.5 |
3x10 |
420 |
16.5 |
3x16 |
610 |
19.0 |
3x25 |
1005 |
21.5 |
3x35 |
1365 |
24.5 |
3x50 |
1780 |
28.5 |
3x70 |
2540 |
32.5 |
3x95 |
3335 |
37.0 |
4x1.5 |
125 |
11.5 |
4x2.5 |
180 |
12.0 |
4x4 |
255 |
13.5 |
4x6 |
345 |
15.5 |
4x10 |
540 |
16.5 |
4x16 |
795 |
21.0 |
4x25 |
1310 |
24.5 |
4x35 |
1760 |
27.0 |
4x50 |
2315 |
32.0 |
5x1.5 |
160 |
11.0 |
5x2.5 |
230 |
13.5 |
7x1.5 |
205 |
13.0 |
7x2.5 |
285 |
15.0 |
12x1.5 |
245 |
16.5 |
12x2.5 |
490 |
18.0 |
19x1.5 |
505 |
19.5 |
19x2.5 |
725 |
22.5 |
27x1.5 |
720 |
24.0 |
37x1.5 |
960 |
27.5 |
|
|
XT marine cables offer a cost effective lightweight method to wiring in marine applications where mechanical protection is not required. Manufactured in accordance with the increasingly popular European standard IEC 60092-353.
Technical Information
Operating temperature: |
-40ºC to +85ºC
(Some +100ºC versions are also available) |
Smoke emission: |
IEC 61034-1 & 2 |
HCl gas emission: |
IEC 60754-1 & 2 |
Flame retardant: |
IEC 60332-3A ( IEC 60332-3-25 ) |
Fire resistant: |
IEC 60331- 3 hours @750ºC |
Approvals: |
Lloyds, DNV, or BV and Rina.
Approvals may vary between manufacture brands.
Please tell us at time of enquiry if you have a specific preference. |
Technical Data
|
No. of Cores
& mm² |
Approx. Weight
Kg/Km |
Nominal
O/D mm |
Single Core
|
1x10 |
190 |
10.5 |
1x16 |
275 |
10.5 |
1x25 |
385 |
12.5 |
1x35 |
490 |
14.0 |
1x50 |
665 |
17.0 |
1x70 |
920 |
19.0 |
1x95 |
1175 |
20.5 |
1x20 |
1460 |
21.5 |
1x150 |
1765 |
24.5 |
1x185 |
2185 |
28.5 |
1x240 |
2820 |
31.0 |
1x300 |
3470 |
33.5 |
2 Core
|
2x1.5 |
140 |
11.5 |
2x2.5 |
185 |
11.0 |
3 Core
|
3x1.5 |
170 |
11.5 |
3x2.5 |
220 |
11.5 |
3x4 |
270 |
14.5 |
3x6 |
380 |
14.5 |
3x10 |
525 |
18.0 |
3x16 |
740 |
20.0 |
3x25 |
1140 |
25.0 |
3x35 |
1505 |
26.5 |
3x50 |
1930 |
30.5 |
3x70 |
2685 |
33.5 |
3x95 |
3600 |
38.5 |
|
No. of Cores
& mm² |
Approx. Weight
Kg/Km |
Nominal
O/D mm |
4 Core
|
4x1.5 |
200 |
12.5 |
4x2.5 |
260 |
12.5 |
4x4 |
355 |
16.0 |
4x6 |
465 |
16.5 |
4x10 |
655 |
19.5 |
4x16 |
935 |
22.0 |
4x25 |
1455 |
26.5 |
4x35 |
1905 |
28.5 |
4x50 |
2495 |
34.5 |
5 Core
|
5x1.5 |
255 |
13.5 |
5x2.5 |
330 |
14.0 |
7 Core
|
7x1.5 |
310 |
15.0 |
7x2.5 |
405 |
16.0 |
12 Core
|
12x1.5 |
475 |
18.0 |
12x2.5 |
630 |
22.0 |
19 Core
|
19x1.5 |
665 |
22.5 |
19x2.5 |
890 |
25.5 |
27 Core
|
27x1.5 |
905 |
27.5 |
37 Core
|
37x1.5 |
1170 |
28.5 |
|
|
|
|